Subject: Zero MDF
Victoria Gill <victoria.gill [at] endangeredheritage__com> writes >I am seeking advice from anyone who has done research on the zero >MDF. I am trying to discuss options for showcases which have had >Zero MDF placed in the floor and the back of the showcase. The >showcase fabric has already been used, *before* consulting a >conservator. I now have the impossible job of mitigating the off >gassing effects. > >Unfortunately the showcases are intended for Asian silk cloths with >metal threads and silver jewelry. Yes the entire exhibition is of >highly sensitive material. The showcases are entirely sealed and >they have a closed humidity controlled system (Munters MG 50 >Desiccant gel dehumidifiers). I must convince the bean counters that >it is worth the cost to remove the cloth and barrier seal the MDF or >replace it. I am considering the barrier recommendation be wrapping >boards in "Intercept" plastic. However drilling for furniture mounts >will perforate the "Intercept" in places and a total seal will not >be entirely possible. Any experience with the dehumidifiers would >also be helpful, this exhibition is in Asia and they have spent a >fortune on products with no prior conservation advice. I can't see >how gels will be practical in the tropics. Any supporting sources >to convince the project managers will be greatly appreciated. In my posting of June 21, 2003 on the Distlist (Conservation DistList Instance: 17:4 Monday, June 23, 2003) I discussed what I had learned about MDF board's permeability. I also did some research on its transference of moisture, but as I mention below, none of this is likely of any real importance in this application. "Intercept" technology comes in a number of forms. One common form of Intercept is as a sheet of copper "doped" polyethylene. This is NOT a good moisture barrier, although one formulation of Intercept film does come integrated with an aluminum barrier film. If you needed to cover the MDF, the important thing would be to get a good barrier film, such as Mitsubushi's Escal, their aluminum foil-based barrier film, Marvelseal, or any other foil-based film. Also note that the MDF board does not need to be "wrapped"; to seal out pollutants and moisture you need only cover the interior surface of the MDF. Most barrier films can be heat sealed directly to the MDF with a regular clothes iron set on low. If the drilling of the mounts perforates the sealing material, this should not be a problem unless air leaks through the holes (they can be sealed with acceptable caulking or covered with foil tape). However, when one steps back and looks at the big picture, you may be over reacting, and no sealing may be necessary! The Munters units use silica gel, but not in the same formulation, or in the same way that a conservator would (as a buffering tool). In the Munters units silica gel in a rotating wheel is dried using hot air. The wheel turns, and a stream of air is then passed through the dried gel and sent to the display case; the now damp silica gel rotates to be dried again, and the generation of dehumidified air proceeds continuously until the unit is turned off. The questions you need to ask are: How much air will be generated and fed into the cases? What is the volume of the display cases? How many cases are there? how many humidity control machines? What is the air exchange rate of the display cases? What is the ambient humidity? How dry will the supplied air be? What is your target humidity? How much humidity variation can you allow? Will the unit turn off if target humidity is reached or keep going? Can you filter the incoming air, etc.? These are standard questions about the microclimate control of a sealed enclosure, and these aspects will affect the build up of pollutants as well. I suspect that you may actually have too much supply air. When all is considered and calculated, it may actually be a good idea to keep moisture moving into the case through the MDF to keep the unit running! As for pollution control, air from the microclimate control units will likely flush pollutants out of the case much faster than they can be generated or transmitted by the MDF. I would suggest discussing this with someone who has some experience with display case climate control before making demands on the bean counters--you might even be able to save them some money. *** Conservation DistList Instance 22:65 Distributed: Friday, May 8, 2009 Message Id: cdl-22-65-003 ***Received on Tuesday, 5 May, 2009