[Table of Contents]


[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [ARSCLIST] Repairing (or purchasing) a Uher



Richard L Hess wrote:
"I think at 15/16 all bets are off as Jay doesn't 
even sell a tape for that speed (I don't think), and I'm not even 
sure there is a standard curve for 15/16 nor 15/32."

IASA TC-04 describes eq curves in terms of time constants, but lists
15/16ips as "undefined". Earlier this year however, Dietrich Schuller
told me that the Phonogrammarchiv had obtained figures for the Uher
curve at 15/16ips, I think from Uher themselves. They are: 3180
microseconds and 159 microseconds.

Regards

Will


..............................................
Will Prentice
Technical Services
British Library Sound Archive    Tel: +44 (0)20-7412-7443
96 Euston Road                   Fax: +44 (0)20-7412-7416
London  NW1 2DB                  http://www.bl.uk 
UK                               http://cadensa.bl.uk (online catalogue)